400-700-9998
欧美大地 Pipe Leakage
Pipe Leakage
Pra-Oil Leakage detection test
发布时间:2018-11-23 浏览次数:1526 来源:欧美大地

The main aim has been to demonstrate the feasibility relative easy integration of this kind of innovative leakage detection system based on distributed fibre optic technology

The area available for the test has allowed the use of approx. 200m polyethylene pipeline buried under 1m of argillaceous soil. The leakage simulation was achieved by hot water injection in the soil through several valves at different positions along the pipe.

 

Aim of monitoring:

The main aim has been to demonstrate the feasibility relative easy integration of this kind of innovative leakage detection system based on distributed fibre optic technology


 

Main results:

The Smartec sensing cable was able to detect any simulated leakage, by localizing every single temperature variation within different border conditions.

INSTALLATION PERIOD TYPE OF SENSORS NUMBER OF SENSORS
2007 DiTeSt / DiTemp 2

Related Papers:

Pipeline Leakage Detection and Localization Using Distributed Fiber Optic Sensing, D. Inaudi, B. Glisic, A. Figini, R. Walder, Rio Pipeline Conference 2007, Rio de Janeiro, Brazil, October 2-4 – 2007
Detection And Localization of Micro-Leakages Using Distributed Fiber Optic Sensing, Daniele Inaudi, Riccardo Belli, Roberto Walder, 7th International Pipeline Conference, IPC2008, 29th September – 3rd October 2008 , Calgary, Alberta, Canada – 2008

为您推荐